When homeowners and businesses invest in solar, they usually focus on panel wattage, inverter brand, and total system cost. Very few realise that one of the biggest factors determining real-world energy production is how the panels are wired — series, parallel, or a hybrid of both. In 2025, with panels routinely exceeding 550–670 W and half-cut TOPCon technology dominating the market, choosing the wrong wiring configuration can cost you 10–30 % of lifetime energy yield.
This in-depth guide explains everything you need to know.
Series vs. Parallel at a Glance (2025 Quick Comparison)
| Factor | Series Wiring | Parallel Wiring | Series-Parallel (Hybrid) |
| Voltage | Adds up (e.g., 4 panels = ~160–200 V) | Stays the same (~40–50 V) | Balanced (80–1 000 V typical) |
| Current (Amps) | Stays the same | Adds up (can exceed 40–60 A) | Moderate |
| Effect of Partial Shading | Entire string can drop dramatically | Only shaded panel affected | Greatly reduced impact |
| Cable thickness required | Thinner (higher voltage, lower current) | Very thick & expensive | Medium |
| Fault tolerance | Low – one failure affects whole string offline | Very high | High |
| Inverter/MPPT compatibility | Needs high-voltage MPPT window | Works with almost any inverter | Most flexible |
| Most common application | Small off-grid, perfect roofs | Heavy shading or microinverter systems | 95 % of modern grid-tied projects |
What Is Series Wiring?
In series wiring, the positive terminal of one panel is connected to the negative terminal of the next, exactly like batteries in a flashlight.
Result:
• Open-circuit voltage (Voc) adds up
• Current (Imp) remains equal to the lowest panel in the string
Example (2025 reality):
Four Sunpal 580 W TOPCon bifacial panels (Voc ≈ 52.8 V, Imp ≈ 13.8 A) wired in series
→ Total ≈ 211 V, still only 13.8 A
Advantages
• Higher voltage = thinner, cheaper cables and lower resistive losses
• Perfect match for modern string inverters with 1 000–1 500 V MPPT ranges
• Simple and low-cost connections (fewer fuses, combiners)
Disadvantages
• If one panel is shaded or dirty, the entire string's current drops to that panel's level (the “Christmas light” effect)
• One failed bypass diode or panel can take the whole string offline
Best for: unshaded south-facing roofs, ground-mount farms with no obstructions, or systems using module-level optimisers.
What Is Parallel Wiring?
In parallel wiring, all positive terminals are connected together and all negative terminals are connected together (usually via MC4 Y-branch connectors).
Result:
• Voltage stays the same as a single panel
• Current adds up
Example:
Same four Sunpal 580 W panels in parallel
→ ~44 V, ≈ 55.2 A
Advantages
• Excellent shading tolerance – a shaded panel only loses its own production
• Extremely high fault tolerance
• Works perfectly with microinverters and low-voltage optimisers
Disadvantages
• Very high current requires thick, expensive cables (10–16 mm² common)
• Higher resistive losses unless cables are kept very short
• Most string inverters cannot accept currents >20–30 A per MPPT
Best for: roofs with chimneys, trees, or multiple orientations; east-west structures; or systems using microinverters (Enphase, Hoymiles, etc.).
The Dominant Choice in 2025: Series-Parallel (Hybrid) Configurations
In the real world, almost no modern installation uses pure series or pure parallel. Instead, engineers create multiple series strings and then connect those strings in parallel at the combiner box or inverter.
Typical residential system (13–20 kW):
• 2–4 strings of 10–14 panels in series (500–800 V)
• Strings then paralleled inside the inverter or DC combiner
This gives you:
• High enough voltage for efficient cable runs
• Reasonable current that doesn't require oversized cables
• Much better shading tolerance than pure series
• Compatibility with module-level power electronics when needed
Sunpal's in-house EPC teams and certified installers use this exact topology in >95 % of projects worldwide.
Six Critical Factors That Decide the Best Wiring for Your Project
1. Shading & Roof Complexity
Even 5 % partial shading on one panel in a series string can cut string output by 30–50 %. Parallel or optimisers are mandatory on complex roofs.
2. Inverter MPPT Voltage Window
Most 2025 string inverters (Growatt, Deye, SMA, SolarEdge, Huawei) accept 180–1 000 V. You must keep your series string within this range in all temperature conditions.
3. Cable Cost & Voltage Drop
Every 1 % voltage drop costs you 1 % energy. Series wiring with thin 6 mm² cable routinely achieves <1 % loss even on 50 m runs.
4. Use of Power Optimisers or Microinverters
Tigo TS4-A-O, SolarEdge P801, or Huawei optimisers make pure series strings almost as shade-tolerant as parallel while keeping cable costs low.
5. System Size & Scalability
Large C&I and utility projects always use high-voltage series-parallel to minimise BOS (balance of system) costs.
6. Local Regulations & Safety
Some countries limit maximum system voltage to 1 000 V DC; others allow 1 500 V. This directly affects how many panels you can put in series.
2025 Technology Trends That Are Changing the Game
• 600–700 W+ modules with Voc routinely >50 V mean fewer panels per string before hitting 1000 V limit
• Half-cut and multi-busbar cells have better low-light and shading behaviour
• Wider MPPT ranges (some inverters now 80–1 500 V)
• Rapid shutdown requirements (NEC 2023 & IEC standards) increasingly favour module-level electronics
• Bifacial panels on flat commercial roofs or ground mounts often use east-west parallel-heavy layouts to capture morning/evening gain
Sunpal's Expert Recommendation After 5 GW+ Deployed Worldwide
For residential and commercial projects, Sunpal almost always recommends:
Series-parallel configuration + selective deployment of module-level power optimisers on shaded panels only (typically 10–20 % of the array).
This combination delivers:
• Highest energy yield (typically 8–18 % more than pure series)
• Lowest levelised cost of electricity (LCOE)
• Maximum system uptime and granularity in monitoring
Our latest Sunpal TOPCon 675–705 W bifacial series, paired with Tigo or SolarEdge optimisers, routinely achieves performance ratios >88 % even on partially shaded urban roofs.
Ready to Maximise Your Solar Production?
The difference between a professional wiring design makes is measured in tens of thousands of dollars over 25–30 years.
Click below to get a free, no-obligation system layout and wiring recommendation from Sunpal's engineering team.
We'll analyse your roof, calculate shading, and deliver a detailed proposal within 24 hours.