Products

ESS Cabinet 125KW/261KWh Liquid-cooled Storage System for C&I

ESS Cabinet 125KW/261KWh

  • Advanced ESS Cabinet 125KW 261KWh
  • 125KW 261KWh Liquid-Cooled Battery Storage System
  • 125KW 261KWh ESS for Commercial & Industrial Use

Advanced ESS Cabinet: 125KW/261KWh Liquid-Cooled Battery Storage System for Commercial & Industrial Use – Efficient, Scalable, and Long-Lasting Energy Solution

Datasheet Download Get Quote
ModelMonet-125CL
Sub-Model125TS(DC100)(261kWh)

Battery Parameters

Battery rated capacity261kWh
Battery rated voltage832V
Battery voltage range728V~936V
Battery typeLFP
Battery cell capacity1P*52S*5S
Cell Capacity314Ah
Max.charging/discharging power0.5P
Max.charge/discharge current157A

Photovoltaic Parameters

PV Output100KW
PV Voltage Range250~500V(MPPT)
PV Max. Current160A*2
MPPT quantity2

AC Parameters

Rated AC power125KW
Rated AC current180A
Rated AC voltage400V, 3W+N+PE
Rated AC frequency50/60Hz
THDi<3(Rated power)
Power Factor-1 leading to+1 lagging
THDv<3% (linear load)

General Parameters

Protection levelIP55
Isolation modeIsolation transformer
Shutdown self-discharge<0.1% Rated power (Without transformer)
DisplayLCD
Relative humidity0 ~ 95% (No condensation)
Noise<78dB
Ambient temperature-25℃ to +60℃(Derating above 45℃)
Cooling modeLiquid-cooled
Altitude3000m(> 2000m derating)
Communication interfaceCAN/Ethernet/485
Dimension (W*D*H)1600*1350*2300mm
Weight (approx.)3330kg

System Connection Diagram

Case

Case Picture

FAQ

Why is LFP battery technology preferred for C&I energy storage?

LFP batteries offer excellent thermal stability, enhanced safety, longer service life, and lower total ownership costs compared with many other lithium battery chemistries.

Does the system support reactive power control?

Yes. The power factor can be adjusted from -1 leading to +1 lagging, allowing flexible grid support and power management.

Why is liquid cooling superior to forced-air cooling for a 125kW / 261kWh cabinet?

Liquid cooling delivers 20%+ longer battery cycle life, lower auxiliary power consumption, and superior cell temperature uniformity compared to air cooling. The closed-loop glycol liquid cooling system maintains cell-to-cell temperature differentials $\le 2.5^\circ\text{C}$ across all 261kWh LFP battery modules, preventing localized thermal hot spots, minimizing capacity degradation, and keeping total operating noise below 65 dB(A).

What is the system AC-to-AC Round-Trip Efficiency (RTE) for the liquid-cooled ESS cabinet?

The system achieves a high AC-to-AC Round-Trip Efficiency (RTE) of $\ge 90%$ under standard 0.5C charge/discharge rates. High RTE is sustained by combining ultra-low-internal-resistance 314Ah/280Ah LiFePO4 cells, a high-efficiency 125kW silicon-carbide (SiC)/IGBT PCS power conversion system, and energy-optimized liquid-cooling pumps that draw less than 3% auxiliary power during thermal-management cycles.